The 1 & 3 MHz Ultrasonic Therapy Unit is a professional physiotherapy device designed to provide therapeutic ultrasonic treatment at two selectable frequencies: 1 MHz and 3 MHz. Having both frequencies in one unit gives physiotherapists greater flexibility to select the appropriate frequency according to the treatment area and clinical requirements.
The unit can be used in physiotherapy clinics, rehabilitation centers, sports therapy facilities, and other professional treatment environments. Exact intensity range, timer, operating modes, applicator specifications, and controls may vary by model.

What Is a 1 & 3 MHz Ultrasonic Therapy Unit?
A 1 & 3 MHz Ultrasonic Therapy Unit is an electrotherapy machine that delivers ultrasonic energy through a handheld treatment applicator.
The two frequencies provide different treatment options:
- 1 MHz – generally selected for deeper tissue applications.
- 3 MHz – generally selected for more superficial tissue applications.
The appropriate frequency, intensity, treatment mode, and duration should always be selected by a qualified physiotherapist based on the patient’s condition and the manufacturer’s instructions.

How Does 1 & 3 MHz Ultrasonic Therapy Work?
The machine generates ultrasonic energy and transfers it through the treatment applicator.
The selected frequency influences how the ultrasonic energy interacts with tissue. In general, 1 MHz penetrates deeper than 3 MHz, while 3 MHz is absorbed more rapidly and is commonly used for more superficial applications.
Ultrasonic therapy may produce mechanical and thermal effects depending on the selected parameters and operating mode.
Key Features of 1 & 3 MHz Ultrasonic Therapy Unit
Dual Frequency: 1 MHz & 3 MHz
The major feature of this unit is its ability to provide both 1 MHz and 3 MHz ultrasonic frequencies from one machine.
Adjustable Intensity
The ultrasonic output intensity can be adjusted according to the treatment requirements and machine specifications.
Continuous & Pulsed Modes
Depending on the model, the unit may provide continuous and pulsed operating modes.
Digital Display
A digital display helps the therapist monitor treatment parameters during the session.

Treatment Timer
A built-in timer helps control the duration of each treatment session.
Handheld Applicator
The ergonomic applicator allows the therapist to deliver ultrasonic energy to the selected treatment area.
Easy-to-Use Controls
The control panel allows convenient selection of frequency, intensity, mode, and treatment duration.
Professional & Compact Design
The unit is suitable for regular use in professional physiotherapy and rehabilitation environments.
1 MHz vs 3 MHz Ultrasonic Frequency
| Feature | 1 MHz | 3 MHz |
|---|---|---|
| Typical application | Deeper tissues | More superficial tissues |
| Tissue absorption | Lower | Higher |
| Relative penetration | Deeper | More superficial |
| Treatment selection | Deeper target areas | Superficial target areas |
| Frequency | 1 MHz | 3 MHz |
Important: Frequency selection should be based on the treatment objective, tissue depth, patient condition, and professional assessment—not simply on the idea that one frequency is universally better.
Applications of 1 & 3 MHz Ultrasonic Therapy Unit
Depending on professional assessment, ultrasonic therapy may be incorporated into:
- Physiotherapy treatment
- Soft-tissue rehabilitation
- Muscle-stiffness management
- Sports rehabilitation
- Selected tendon and ligament rehabilitation
- Joint-related rehabilitation
- Tissue-warming applications
- Pre-exercise preparation
- Selected musculoskeletal treatment programs
The machine should only be used when ultrasonic therapy is considered appropriate.

Benefits of 1 & 3 MHz Ultrasonic Therapy Unit
The 1 & 3 MHz Ultrasonic Therapy Unit can provide several practical advantages:
- Two ultrasonic frequency options
- 1 MHz for deeper applications
- 3 MHz for more superficial applications
- Adjustable treatment intensity
- Continuous and pulsed modes on supported models
- Digital display
- Treatment timer
- Handheld applicator
- Easy treatment parameter selection
- Flexible professional use
- Suitable for physiotherapy clinics
- Useful for rehabilitation environments
- One machine covering two commonly used frequencies
How to Use 1 & 3 MHz Ultrasonic Therapy Unit
The machine should be operated by a trained physiotherapist or qualified healthcare professional. Always follow the manufacturer’s instructions for the exact model.
Step 1: Assess the Patient
Assess the patient’s condition and determine whether ultrasonic therapy is appropriate.
Identify the treatment area and determine whether 1 MHz or 3 MHz is more appropriate.
Step 2: Check the Machine
Before starting, inspect:
- Power cable
- Applicator head
- Applicator cable
- Digital display
- Control panel
- Connectors
Do not use the machine if any component is damaged.
Step 3: Prepare the Treatment Area
Expose the selected treatment area.
Ensure the skin is clean and suitable for treatment.
Step 4: Apply Coupling Gel
Apply an appropriate amount of ultrasonic coupling gel over the treatment area.
The gel helps maintain effective contact between the applicator and skin.
Step 5: Select the Frequency
Select the appropriate frequency:
1 MHz for deeper treatment applications or
3 MHz for more superficial treatment applications.
The exact choice should be made by the treating professional.
Step 6: Select the Treatment Mode
Depending on the model, select:
- Continuous mode
- Pulsed mode
Choose the appropriate mode according to the treatment protocol.

Step 7: Set the Intensity
Set the required ultrasonic intensity according to the patient’s condition and professional treatment plan.
Avoid unnecessarily high output.
Step 8: Set the Timer
Set the required treatment duration using the machine’s timer.
Step 9: Position the Applicator
Place the applicator gently against the skin with adequate coupling gel.
Maintain proper contact during treatment.
Step 10: Move the Applicator
Move the applicator slowly and continuously over the selected treatment area using the recommended professional technique.
Do not leave an active applicator stationary over one spot unless specifically permitted by the manufacturer’s instructions.
Step 11: Monitor the Patient
Monitor the patient throughout the session.
Ask about:
- Pain
- Excessive warmth
- Discomfort
- Unusual sensations
Stop treatment if significant discomfort or an unexpected reaction occurs.
Step 12: Complete the Treatment
When the timer finishes, stop the ultrasonic output before removing the applicator.
Remove the coupling gel and clean the applicator according to the manufacturer’s instructions.
Safety Precautions
- Use the machine under qualified professional supervision.
- Follow the manufacturer’s operating instructions.
- Check the applicator and cables before every session.
- Use an appropriate coupling medium.
- Maintain proper applicator contact.
- Do not leave an active applicator stationary unless specifically permitted.
- Avoid excessive intensity or treatment duration.
- Monitor the patient’s comfort throughout treatment.
- Use additional caution where sensation is reduced.
- Do not use over unsuitable or damaged skin.
- Follow professional contraindication guidelines.
- Stop treatment if significant pain, excessive heat, or unusual discomfort occurs.
- Clean the applicator after every treatment according to the manufacturer’s instructions.
Things to Check Before Buying
Before purchasing a 1 & 3 MHz Ultrasonic Therapy Unit, check these important points:
1. Dual Frequency
Confirm that the machine genuinely supports both 1 MHz and 3 MHz frequencies.
2. Intensity Range
Check the available ultrasonic intensity range.
3. Operating Modes
Check whether the machine offers continuous and pulsed modes.
4. Applicator Head
Check the applicator size, construction, cable quality, and treatment-area suitability.

5. Digital Display
A clear digital display makes treatment parameters easier to monitor.
6. Timer
Check the available treatment-time range.
7. Frequency Selection
Ensure switching between 1 MHz and 3 MHz is simple and clearly indicated.
8. Warranty & Service
Check warranty coverage and after-sales technical support before purchasing.
Who Should Operate a 1 & 3 MHz Ultrasonic Machine?
The 1 & 3 MHz Ultrasonic Therapy Unit should be operated by a trained physiotherapist or qualified healthcare professional.
The professional should determine the appropriate frequency, treatment area, intensity, mode, duration, and application technique according to the patient’s condition and manufacturer’s instructions.
Why Choose a Dual-Frequency Ultrasonic Therapy Unit?
A dual-frequency machine provides greater treatment flexibility compared with a single-frequency ultrasonic unit.
Instead of purchasing separate machines for different frequency requirements, a 1 & 3 MHz Ultrasonic Therapy Unit combines both options into one professional device.
This makes it a practical choice for clinics that manage patients requiring different treatment depths and applications.

Conclusion
The 1 & 3 MHz Ultrasonic Therapy Unit is a professional physiotherapy machine offering two commonly used ultrasonic frequencies in one device.
Its combination of 1 MHz and 3 MHz frequency selection, adjustable intensity, continuous/pulsed modes on supported models, digital controls, timer, and handheld applicator makes it a versatile option for physiotherapy and rehabilitation environments.
For safe and appropriate treatment, the frequency, intensity, duration, and application technique should always be selected by a qualified professional according to the patient’s condition and manufacturer’s instructions.
Frequently Asked Questions
1. What is a 1 & 3 MHz Ultrasonic Therapy Unit?
It is an ultrasonic physiotherapy machine that provides both 1 MHz and 3 MHz treatment frequencies.
2. What is the difference between 1 MHz and 3 MHz?
1 MHz is generally used for deeper tissue applications, while 3 MHz is generally used for more superficial applications.
3. Does ultrasonic therapy require gel?
Yes, an appropriate coupling gel is generally used between the applicator and skin.
4. Can the ultrasonic intensity be adjusted?
Yes, the intensity can be adjusted according to the machine’s available settings and treatment plan.
5. Who should operate the machine?
A trained physiotherapist or qualified healthcare professional should operate it.